Update argyllcms to 3.5.0 Change log since 3.4.1: Version 3.5.0 4th February 2026 ------------- * Added MSWindows ARM release. * Added Mac ARM release. * Removed Mac PowerPC build from release. * Added test profile forward and backward lookup error checks to release sanity checking script. * Changed colprof so that rather than just warning about an ink limit being set for an additive device space, it ignores it. * Fixed bug in targen introduced in V3.3.0 where it adds a default ink limit for all device types. If not overidden later in the profiling process, this can introduce an ink limit 10% less than the unconstrained limit. This is a problem for additive devices. * Fixed reported problem with some models of Spyder2024. * Upgraded built-in libpng to V1.6.51 * Upgraded built-in zlib to V1.3.1 * Took a stab at adding libusb-win32 ARM64 system driver support. Reported to work, but installing libusb-win32 system driver is more difficult. * Added Munsell Linear Grayscale scanin reference files. (Thanks to Tarek A. Haila and Frank Schaumann) * Added -g option to xicc/fakeCMY to emit RGB values rather than CMY values. * Tweaked i1d3 frequency measurement mode to return exactly zero on measuring perfect black rather than the correctly rounded value, so as to make it more consistent with the period measurement mode. This inconsistency shows up with a Rev. B when I1D3_DISABLE_AIO is set and the 0x83 bug is triggered, and frequency measurement is used as a fallback to period measurement mode. Rev. A instruments shouldn't see any change since for them the period measurement mode doesn't suffer from the 0x83 bug. * Added -o observer option to xicc/specplot * Improved robustness of command name filename parsing in a number of utilities. * Expand spectro/average to handle input test charts. * Improve JETI Specbos 2501 operation.
update argyllcms to 3.4.0
pkgsrc changes:
- depend on openssl to avoid it accidentially beind found but unlinkable
- handle new com.argyllcms.metainfo.xml file
- refresh line numbers in spectro/icoms_ux.c patch
upstream changelog:
[V3.3.0 -> V3.4.0] 8th July 2025
- Added support for Spyder and SpyderPRO (2024)
- Renamed proposed CIE 2012 2 and 10 degree to standard CIE 2015 2 and 10
degree observers, as per CIE 170-2:2015.
- Added -Y c: option to colprof and invprofcheck to allow
setting/overriding alibration curves for setting final ink limits.
- Added -Y c: option to xicclu to allow setting/overriding calibration
curves for setting final ink limits, and added -T flag to show ink
limits.
- Fixed Spyder X and X2 to not make Device Disconect noise (if such sounds
are enabled) on MSWin.
- Fixed bug in colprof -nI failing for CMYK profiles.
- Enhanced strip reader patch recognition to reject strips that don't
start and end on the media, as well as adding some speed compensation to
the patch recognition for non-zerbra ruler measurements.
- Fixed bug in i1Pro3 strip reading where it would return bad values if
the zerbra stripe wasn't used.
- Changed chartread so that it will issue warnings of possible bad row or
patch reading even when .ti2 reference measurement is not accurate (i.e.
no preconditioning profile used in targen.)
- Increased emphasis of making sure that there is contrast between patches
at the end of rows in printtarg patch ordering for strip instruments.
- Added -C parameter to targen to allow overriding any calibration curves
found in the ICC profile, used to estimage the total ink limit from that
in the ICC profile. Also better enforces final raw computes ink limits.
- Modified ccxxmake so that it checks that it has actually found a white
seeming patch to use as the L*a*b* white reference, and the patch to
de-weight. If there is no white patch (i.e. just RGB patches) then it
will use D65 as the L*a*b* conversion reference. ccxxmake will fail if
there are less than 3 patches.
- Fixed ICC profile writing so that it clips rather than failing when
writing a ColorantTable PCS value that is out of range. A warning to
stderr will be issued.
- Changed ColorMunki driver so that it is more forgiving about unexpected
version string lengths.
- Fixed dispcal and dispread so that they won't error out if there is no
instrument but the -M parameter is provided.
Add ArgyllCMS 3.0.2 ArgyllCMS is an ICC compatible color management system, available as Open Source. It supports accurate ICC profile creation for scanners, cameras and film recorders, and calibration and profiling of displays and RGB & CMYK printers. Device Link can be created with a wide variety of advanced options, including specialized Video calibration standards and 3dLuts.