The NetBSD Project

CVS log for pkgsrc/graphics/argyllcms/PLIST

[BACK] Up to [cvs.NetBSD.org] / pkgsrc / graphics / argyllcms

Request diff between arbitrary revisions


Keyword substitution: kv
Default branch: MAIN


Revision 1.3: download - view: text, markup, annotated - select for diffs
Wed Feb 11 02:41:15 2026 UTC (9 months ago) by jakllsch
Branches: MAIN
CVS tags: pkgsrc-2026Q3-base, pkgsrc-2026Q3, pkgsrc-2026Q2-base, pkgsrc-2026Q2, pkgsrc-2026Q1-base, pkgsrc-2026Q1, HEAD
Diff to: previous 1.2: preferred, colored
Changes since revision 1.2: +3 -1 lines
Update argyllcms to 3.5.0

Change log since 3.4.1:

Version 3.5.0  4th February 2026
-------------

 * Added MSWindows ARM release.

 * Added Mac ARM release.

 * Removed Mac PowerPC build from release.

 * Added test profile forward and backward lookup error checks to
   release sanity checking script.

 * Changed colprof so that rather than just warning about an ink limit
   being set for an additive device space, it ignores it.

 * Fixed bug in targen introduced in V3.3.0 where it adds a default
   ink limit for all device types. If not overidden later in the
   profiling process, this can introduce an ink limit 10% less
   than the unconstrained limit. This is a problem for additive devices.

 * Fixed reported problem with some models of Spyder2024.

 * Upgraded built-in libpng to V1.6.51

 * Upgraded built-in zlib to V1.3.1

 * Took a stab at adding libusb-win32 ARM64 system driver support.
   Reported to work, but installing libusb-win32 system driver
   is more difficult.

 * Added Munsell Linear Grayscale scanin reference files.
   (Thanks to Tarek A. Haila and Frank Schaumann)

 * Added -g option to xicc/fakeCMY to emit RGB values rather
   than CMY values.

 * Tweaked i1d3 frequency measurement mode to return exactly
   zero on measuring perfect black rather than the correctly
   rounded value, so as to make it more consistent with the
   period measurement mode. This inconsistency shows up with a
   Rev. B when  I1D3_DISABLE_AIO is set and the 0x83 bug
   is triggered, and frequency measurement is used as a fallback
   to period measurement mode.
   Rev. A instruments shouldn't see any change since for them
   the period measurement mode doesn't suffer from the 0x83 bug.

 * Added -o observer option to xicc/specplot

 * Improved robustness of command name filename parsing in a number of utilities.

 * Expand spectro/average to handle input test charts.

 * Improve JETI Specbos 2501 operation.

Revision 1.2: download - view: text, markup, annotated - select for diffs
Sun Jul 13 12:59:03 2025 UTC (16 months ago) by jakllsch
Branches: MAIN
CVS tags: pkgsrc-2025Q4-base, pkgsrc-2025Q4, pkgsrc-2025Q3-base, pkgsrc-2025Q3
Diff to: previous 1.1: preferred, colored
Changes since revision 1.1: +2 -1 lines
update argyllcms to 3.4.0

pkgsrc changes:
    -   depend on openssl to avoid it accidentially beind found but unlinkable
    -   handle new com.argyllcms.metainfo.xml file
    -   refresh line numbers in spectro/icoms_ux.c patch

upstream changelog:

[V3.3.0 -> V3.4.0] 8th July 2025

    -   Added support for Spyder and SpyderPRO (2024)
    -   Renamed proposed CIE 2012 2 and 10 degree to standard CIE 2015 2 and 10
        degree observers, as per CIE 170-2:2015.
    -   Added -Y c: option to colprof and invprofcheck to allow
        setting/overriding alibration curves for setting final ink limits.
    -   Added -Y c: option to xicclu to allow setting/overriding calibration
        curves for setting final ink limits, and added -T flag to show ink
        limits.
    -   Fixed Spyder X and X2 to not make Device Disconect noise (if such sounds
        are enabled) on MSWin.
    -   Fixed bug in colprof -nI failing for CMYK profiles.
    -   Enhanced strip reader patch recognition to reject strips that don't
        start and end on the media, as well as adding some speed compensation to
        the patch recognition for non-zerbra ruler measurements.
    -   Fixed bug in i1Pro3 strip reading where it would return bad values if
        the zerbra stripe wasn't used.
    -   Changed chartread so that it will issue warnings of possible bad row or
        patch reading even when .ti2 reference measurement is not accurate (i.e.
        no preconditioning profile used in targen.)
    -   Increased emphasis of making sure that there is contrast between patches
        at the end of rows in printtarg patch ordering for strip instruments.
    -   Added -C parameter to targen to allow overriding any calibration curves
        found in the ICC profile, used to estimage the total ink limit from that
        in the ICC profile. Also better enforces final raw computes ink limits.
    -   Modified ccxxmake so that it checks that it has actually found a white
        seeming patch to use as the L*a*b* white reference, and the patch to
        de-weight. If there is no white patch (i.e. just RGB patches) then it
        will use D65 as the L*a*b* conversion reference. ccxxmake will fail if
        there are less than 3 patches.
    -   Fixed ICC profile writing so that it clips rather than failing when
        writing a ColorantTable PCS value that is out of range. A warning to
        stderr will be issued.
    -   Changed ColorMunki driver so that it is more forgiving about unexpected
        version string lengths.
    -   Fixed dispcal and dispread so that they won't error out if there is no
        instrument but the -M parameter is provided.

Revision 1.1: download - view: text, markup, annotated - select for diffs
Fri Nov 17 17:37:48 2023 UTC (2 years, 11 months ago) by jakllsch
Branches: MAIN
CVS tags: pkgsrc-2025Q2-base, pkgsrc-2025Q2, pkgsrc-2025Q1-base, pkgsrc-2025Q1, pkgsrc-2024Q4-base, pkgsrc-2024Q4, pkgsrc-2024Q3-base, pkgsrc-2024Q3, pkgsrc-2024Q2-base, pkgsrc-2024Q2, pkgsrc-2024Q1-base, pkgsrc-2024Q1, pkgsrc-2023Q4-base, pkgsrc-2023Q4
Add ArgyllCMS 3.0.2

ArgyllCMS is an ICC compatible color management system, available
as Open Source. It supports accurate ICC profile creation for
scanners, cameras and film recorders, and calibration and profiling
of displays and RGB & CMYK printers. Device Link can be created
with a wide variety of advanced options, including specialized
Video calibration standards and 3dLuts.

Diff request

This form allows you to request diffs between any two revisions of a file. You may select a symbolic revision name using the selection box or you may type in a numeric name using the type-in text box.

Log view options

CVSweb <webmaster@jp.NetBSD.org>