[BACK]Return to files.i2c CVS log [TXT][DIR] Up to [cvs.NetBSD.org] / src / sys / dev / i2c

Please note that diffs are not public domain; they are subject to the copyright notices on the relevant files.

Diff for /src/sys/dev/i2c/files.i2c between version 1.16 and 1.16.30.2

version 1.16, 2007/09/02 01:40:46 version 1.16.30.2, 2008/12/13 01:14:13
Line 1 
Line 1 
 #       $NetBSD$  #       $NetBSD$
   
   defflag opt_i2cbus.h                            I2C_SCAN
 define  i2cbus { }  define  i2cbus { }
 define  i2cexec  define  i2cexec
   
 device  iic { addr, [size = -1] }  device  iic { [addr = -1], [size = -1] }
 attach  iic at i2cbus  attach  iic at i2cbus
 file    dev/i2c/i2c.c                           iic | i2cbus  file    dev/i2c/i2c.c                           iic | i2cbus
 file    dev/i2c/i2c_exec.c                      iic | i2cbus | i2cexec  file    dev/i2c/i2c_exec.c                      iic | i2cbus | i2cexec
Line 48  device lmtemp: sysmon_envsys
Line 49  device lmtemp: sysmon_envsys
 attach  lmtemp at iic  attach  lmtemp at iic
 file    dev/i2c/lm75.c                          lmtemp  file    dev/i2c/lm75.c                          lmtemp
   
   # National Semiconductor LM78 temp sensor/fan controller
   attach  lm at iic with lm_iic
   file    dev/i2c/lm_i2c.c                        lm_iic
   
 # Dallas DS1307 Real Time Clock  # Dallas DS1307 Real Time Clock
 device  dsrtc  device  dsrtc
 attach  dsrtc at iic  attach  dsrtc at iic
Line 58  device xrtc
Line 63  device xrtc
 attach  xrtc at iic  attach  xrtc at iic
 file    dev/i2c/x1226.c                         xrtc  file    dev/i2c/x1226.c                         xrtc
   
 # Analog Devices ADT 7463 thermal monitor / fan controller  # Analog Devices dBCool family of thermal monitors / fan controllers
 define adt7463c {}  define dbcool {}
 device adt7463c: sysmon_envsys  device dbcool: sysmon_envsys
 attach adt7463c at iic  attach dbcool at iic
 file dev/i2c/adt7463.c                  adt7463c  file dev/i2c/dbcool.c                   dbcool
   
 # Analog Devices ADT 7467 thermal monitor / fan controller  
 define adt7467c {}  
 device adt7467c: sysmon_envsys  
 attach adt7467c at iic  
 file dev/i2c/adt7467.c                  adt7467c  
   
 # Analog Devices ADM 1030 thermal monitor / fan controller  
 define adm1030c {}  
 device adm1030c: sysmon_envsys  
 attach adm1030c at iic  
 file dev/i2c/adm1030.c                  adm1030c  
   
 # RICOH RS5C372[AB] Real Time Clock  # RICOH RS5C372[AB] Real Time Clock
 device  rs5c372rtc  device  rs5c372rtc
Line 112  file dev/i2c/xbseeprom.c  xbseeprom
Line 105  file dev/i2c/xbseeprom.c  xbseeprom
 device  spdmem  device  spdmem
 attach  spdmem at iic  attach  spdmem at iic
 file    dev/i2c/spdmem.c                spdmem  file    dev/i2c/spdmem.c                spdmem
   
   # ADM1021
   device  admtemp: sysmon_envsys
   attach  admtemp at iic
   file    dev/i2c/adm1021.c               admtemp

Legend:
Removed from v.1.16  
changed lines
  Added in v.1.16.30.2

CVSweb <webmaster@jp.NetBSD.org>